| CTI Journal | |||||
| [HKCU_CTI_Journal] = HKCU\Software\ROMICO\CTI_Journal | |||||
| [HKCU_TeliBar] = HKCU\Software\ROMICO\TeliBar | |||||
| Settings | |||||
| RedirectedCallsFrom_ Me_Show |
[HKCU_CTI_Journal]\ Settings | "RedirectedCallsFromMe_Show"="0" | If flag is set
to "1" are shown all calls to numbers on which call was redirected,
when it is not answered by me. In case value "0" the entries are
not shown. [default "1"][restart not necessary]. |
CTI_Journal_Settings_ RedirectedCallsFromMe_ Show_0.reg |
TeliBar.exe:
>= 2.0.0.5220; 12.06.2013 |
| UserGroupID | [HKCU_CTI_Journal] \ Settings | UserGroupID = "1" | UserGroupID, needed for SQL
queries for Protocol.mdb in gruop mode. (Default="") |
||
| UserName | [HKCU_CTI_Journal] \ Settings | UserName = "Kuba" | Username (Default = "") | ||
| ProtocolSQLServer | [HKCU_CTI_Journal] \ Settings | ProtocolSQLServer="srv\SQLEXPRESS" | [default ""] | CTI_Journal_ ProtocolSQLServer.reg |
|
| ProtocolSQLDBName="'TeliManOther" | MSSQL database name. [default "TeliMan"] | ||||
| ProtocolMdbPath | [HKCU_CTI_Journal] \ Settings | ProtocolMdbPath="C:\Programme\TeliMan Pro Server\TMServer\Protocol.mdb" | [default ""] | ||
| ProtocolDatabaseType | [HKCU_CTI_Journal] \ Settings | ProtocolDatabaseType="sql" | [default "mdb"] | CTI_Journal_ ProtocolDatabaseTypeSql.reg |
|
| MakeCallType | [HKCU_CTI_Journal] \ Settings | MakeCallType="tmc" | [default "TeliBar"] | CTI_Journal_Settings_ MakeCallType.reg |
26.09.2008; 1.0.0.254 |
| ProtocolCheckInterval | [HKCU_CTI_Journal] \ Settings | ProtocolCheckInterval = "10" | Protocol refresh inteval in seconds [default = '4'] | CTI_Journal_ ProtocolCheckInterval.reg |
26.09.2008; 1.0.0.254 |
| GroupJournal_Block | [HKCU_CTI_Journal] \ Settings | GroupJournal_Block="1" | blocking show Group menu [default "0"] | CTI_Journal_Settings_ MakeCallType.reg |
10.08.2009; 1.0.0.407 |
| ServerMode | [HKCU_CTI_Journal] \ Settings | "ServerMode"="1" | CTI_Journal will be executed in Server Mode (no user filtering) when this flag is set to 1. [Default = "0"] | CTI_Journal_ServerMode_1.reg | 19.09.2009; 1.0.0.539 |
| Flag of default device for play recorded message | [HKCU_CTI_Journal] \ Settings | "MailBox_PlayDevice"="Phone" | Flag of default device for play
recorded message. If Windows then play by MediaPlayer, if "Phone"
then call my phone num and play recorded message by CCU [default "Phone"] |
CTI_Journal_MailBox_ PlayDevice_Windows.reg |
CTI-Journal:
23.07.2012; 1.0.0.765 CTI-Client: 23.07.2012; 2.0.0.4292 |
| Flag of default device for play recorded message | [HKCU_CTI_Journal] \ Settings | "MailBox_PlayDevice"="Phone" | Flag of default device for play recorded message. If Windows then play by MediaPlayer, if "Phone" then call my phone num and play recorded message by CCU [default "Windows"] | CTI_Journal_MailBox_ PlayDevice_Phone.reg |
21.06.2010; 1.0.0.765 |
| RowsDelete_Enable | [HKCU_CTI_Journal] \ Settings | "RowsDelete_Enable" = "1" | Enable rows deleting from protocol by CTI_Journal (by context menu or “DELETE” key). [ServerMode_Default: “1”, ClientMode_Default: “0”] | CTI_Journal_RowsDelete _Enable.reg |
20.10.2009; 1.0.0.817 |
| ProtocolMainField | [HKCU_CTI_Journal] \ Settings | "ProtocolMainField" = "UserLine" | Change main protocol column. Changing main column changes also SQL filter while loading calls. [Default=”UserName”, possible values: {“UserName”, “UserLine”},{“Both”}] | CTI_Journal_ ProtocolMainField.reg |
20.10.2009;
1.0.0.817 {“Both”} - 16.11.2011; 1_0_1276 |
| ProtocolLocal CallUpdateDelay |
[HKCU_CTI_Journal]\ Settings | "ProtocolLocalCallUpdateDelay" = “120” | Time in seconds used to delay protocol update after loading call info from registry saved by TeliBar. [Default: “15”] | CTI_Journal_ProtocolLocal CallUpdateDelay_120.reg |
TeliBar.exe:2.0.0.765; 08.11.2010 |
| ProtocolLocal CallUpdateDelay |
[HKCU_CTI_Journal]\ Settings | "ProtocolLocalCallUpdateDelay" = “1” | Time in minutes used to delay protocol update after loading call info from registry saved by TeliBar. [Default: “5”] | CTI_Journal_ProtocolLocal CallUpdateDelay_1.reg |
TeliBar.exe:2.0.0.759; 03.11.2010 |
| LocalSearchResult UpdateToProtocolDB |
[HKCU_CTI_Journal]\ Settings | "LocalSearchResultUpdateToProtocolDB"="0" | Key
used to enable calls update using contacts info from local RefSearch
database. “0” – mechanism turned off. “1” – update all calls in protocolDB from last 24hrs. “2” - update only calls with empty Name1, Name2 and Company fields in protocolDB from last 24hrs. [default "2"] |
CTI_Journal_LocalSearchResult UpdateToProtocolDB_0.reg |
TeliBar.exe:
2_0_850; 15.12.2010 |
| LocalSearchResult UpdateToProtocolDB |
[HKCU_TeliBar]\ CTI_Journal | "LocalSearchResultUpdateToProtocolDB"="0" | When true after call search local DB and update entry to protocol DB[default "1"] | TeliBar_CTI_Journal_LocalSearch ResultUpdateToProtocolDB_0.reg |
TeliBar.exe:2.0.0.759;
03.11.2010 TeliBar.exe<2_0_850; 15.12.2010 |
| LocalSearchResult UpdateToProtocolDB |
[HKCU_TeliBar]\ CTI_Journal | LocalSearchResultUpdateToProtocolDB="-1" | When true after call search local DB and update entry to protocol DB[default "0"] | TeliBar_CTI_Journal_LocalSearch ResultUpdateToProtocolDB_1.reg |
TeliBar.exe:2.0.0.205;
01.06.2010 TeliBar.exe<2.0.0.759; 03.11.2010 |
| TrayIcon_ BlinkOnNewCall |
[HKCU_CTI_Journal]\ Settings | "TrayIcon_BlinkOnNewCall" ="0" | If key is set then CTI_Journal starts blinking tray icon on incomming call, Today filter and client mode. [default "1"] | CTI_Journal_TrayIcon_ BlinkOnNewCall_0.reg |
TeliBar.exe: 2_0_850; 15.12.2010 |
| DetectIdle_ SetTodayFilter_ Timeout |
[HKCU_CTI_Journal]\ Settings | "DetectIdle_SetTodayFilter_Timeout" ="0" | Value
used as timeout for detecting that form is inactive in minutes. If key = “0” then CTI_Journal does not detect that form is inactive. [default "3"][min] |
CTI_Journal_DetectIdle_ SetTodayFilter_Timeout_0.reg |
TeliBar.exe:
2_0_850; 15.12.2010 TeliBar.exe < 2_0_4297; 25.07.2012 |
| DetectIdle_ SetTodayFilter_ Timeout_s |
[HKCU_CTI_Journal]\ Settings | "DetectIdle_SetTodayFilter_Timeout_s" ="0" | Value used as timeout for detecting that form is inactive in
seconds. If key = “0” then CTI_Journal does not detect that form is inactive. [default "15"][sec] [restart not necessary]. |
CTI_Journal_DetectIdle_ SetTodayFilter_Timeout_0.reg |
TeliBar.exe: 2_0_4297; 25.07.2012 |
| ColumnTargetID_ Visible |
[HKCU_CTI_Journal]\ Settings | “ColumnTargetID_Visible”=”0” | If
flag is set then CT_Journal shows TargetID column containing redirection
destination number of call. [default = “1”]. Restart necesarry. |
CTI_Journal_Column TargetID_Visible_0.reg |
TeliBar.exe: 2_0_1807; 21.03.2011 |
| PhoneNumber _EditableIfEmpty |
[HKCU_CTI_Journal]\ Settings | "PhoneNumber_EditableIfEmpty" ="0" | If flag is set then CT_Journal allows editing PhoneNumber if it is empty. [default "1"][restart necessary]. | CTI_Journal_Settings_ PhoneNumber_ EditableIfEmpty_0.reg |
TeliBar.exe: 2.0.0.4579; 04.12.2012 |
| Filter_ UseTimeForMarked |
[HKCU_CTI_Journal]\ Settings | "Filter_UseTimeForMarked" ="1" | If flag is set then it is now possible to use time filter with bold calls filter. [default "0"][restart not necessary]. | CTI_Journal_Settings_Filter _UseTimeForMarked_1.reg |
TeliBar.exe: 2.0.0.4583; 21.12.2012 |
| MaxRowsCount | [HKCU_CTI_Journal]\ Settings | "MaxRowsCount"="200" | Max protocol entries count. [default "10000"][restart not necessary]. | CTI_Journal_Settings_ MaxRowsCount_200.reg |
TeliBar.exe: >= 2.0.0.4893; |
| MaxRowsCount | [HKLM_CTI_Journal]\ Settings | "MaxRowsCount"="200" | Max protocol entries count. [default "10000"][restart not necessary]. | CTI_Journal_Settings_ MaxRowsCount_200.reg |
TeliBar.exe: < 2.0.0.4893; |
| Debug | |||||
| MaxLogRowsCount | [HKCU_CTI_Journal] \ Debug | MaxLogRowsCount=2000 | [default "200"] | ||
| DebugLog | [HKCU_CTI_Journal] \ Debug | DebugLog=1 | [default "0"] | ||
| DebugLogPerformanc | [HKCU_CTI_Journal] \ Debug | DebugLogPerformance=1 | [default "0"] | ||
| Debug | [HKCU_CTI_Journal] | Debug=1 | [default "0"] | ||
| Show Debug window | C:\Programme\ROMICO\TeliBar\CTI_Journal.exe DEBUG | ||||
| Ctl+Alt+Shit+D | |||||